Sensor graph
Sensor Graph
最終更新
Sensor Graph
最終更新
Windows
macOS
Linux
RasPi
Various sensor data are recorded in a database file. There is also a function to simply refer to the measured values on the TWELITE Stage screen.
It is not possible to start multiple TWELITE STAGE with the same executable name and use the sensor graph at the same time.
The database file is stored in the {MWSTAGE installation}/log
folder and the file name is determined by the TWELITE_Stage executable name.This is because the same executable file name refers to the same database file. The TWELITE STAGE app implementation does not expect multiple application instances to be adding data to the database at the same time. In some situations, this may result in a database file access error, which may cause the TWELITE STAGE app to crash.
For example, if you want to connect two MONOSTICKs and run multiple "sensor graphs" at the same time, run the TWELITE STAGE application with different executable names (stage_a.exe
, stage_b.exe
) for each. The database file names are log/stage_a_WSns.sqlite
and log/stage_b_WSns.sqlite
.
Data is stored in a file named {MW_STAGE Install}/log/{MW_STAGE file name}_WSns.sqlite
using sqlite3.
The screen transition is [List (with graph preview)]>[24-hour data]>[Live View].
From [24-hour data], you can move to [Year], [Month], [Day (with graph preview)] selection screen.
About the [Live] display screen
Select a specific node from the list.
Display real-time data every second, up to 450 seconds in the past.
About [24-hour data] display screen
Display data for a specific day.
Data is acquired every second, and if there are multiple data, they will be thinned out.
Except for the maximum magnification (1 second per pixel), the data is displayed by averaging the acquired values in each pixel range.
If the value extends beyond the screen, the measurement points are displayed at the top and bottom edges.
If the current time is included, the display is updated when new data arrives.
Wheel, cursor up/down: zoom in/out of time axis
Mouse move: Simplified display of the acquired data in the time axis corresponding to the mouse pointer.
Cursor→, ←: Move to the next acquisition data.
Click and drag: Scroll (only when zoomed in)
When zoomed in, operation by scroll bar is also available.
The [CSV Output] function displays all acquired values contained in the database.
Use the tools at https://sqlitebrowser.org/ to extract data.
Mouse drag (graph area)
Move the display position when zooming in
Mouse drag (bottom scroll bar)
Move the display position when zooming in
Cursor →, ←
Move the sample display
Cursor up, down, wheel
Zoom in/out on sample horizontal axis
[LIVE>>]
Go to the one-second increment view that displays the latest arrival data
[24Hr Data]
Go to daily graph
[<Nodes]
Go to the nodes selection screen
[Yr]
[Mo]
[Dy]
Select a specific date by year, month, and day.
[ltst]
Go to today's data
[CSV exprot]
Output one day's data to CSV file
[DISP]
at Nodes screen
Change the display method of the list
[SORT]
at Nodes screen
Change the order of the list
[↑]
at Nodes screen
Reverses the order of the listings
v1.3.9
or later
On the "24-hour data screen," left-clicking on the memo portion of the sensor node in the upper right corner of the screen will prompt you to edit the memo.
ASCII charavcters
If you enter a normal alphanumeric string directly, it will be switched accordingly on the screen.
BS
Delete the trailing characters displayed.
ENTER
The entered string is reflected in the database.
IME input operations (e.g. Japanese) may depend on the system you are using.
Unexpected character strings may be input depending on the operation at the time of IME input. When an unnecessary string is displayed in the input area, delete the unnecessary part by pressing the BS
key.
There are three basic types of screens: list, 24-hour, and live.
Specify 32
in [STAGE Common Settings -> Startup Application Designation].
_uqid
INTEGER
continuation number used in the database
sid
INTEGER
int32_t
serial number stored in int32_t
type." In the case of the serial number "8123abcd", the integer value of -2,128,368,691 is stored.
ts
INTEGER
The time the system received the packet, a timestamp value stored of type int64_t
UNIX epoch (seconds elapsed since 1970).
ts_msec
INTEGER
The milliseconds portion of the timestamp.
year
INTEGER
The year portion of the local time from the timestamp.
month
INTEGER
The month portion of the local time from the timestamp.
day
INTEGER
The day portion of the local time relative to the timestamp.
hour
INTEGER
The hour portion of local time from the time stamp.
lid
INTEGER
The identification value, e.g., LID, assigned by the user.
lqi
INTEGER
Approximate value of the reception strength (Link Quality Indicator).
pkt_seq
INTEGER
The sequential number of the packet. The possible values depend on the firmware.
pkt_type
INTEGER
The type of wireless packet.
2 PAL AMB, 6 ARIA
1 PAL MAG
*3 PAL MOT,5 CUE
0x101 App_Twelite, *0x103 App_IO
*Not supported at this time
value
REAL
measured value (definition depends on packet type)
pkt_type->
2,6: temperature
1: presence of magnet 00->no magnet, 01->N-pole, 02->S-pole
3,5: X axis acceleration (average if packet includes multiple 0x101,103: bitmap of input IO (same value as the last 8 bits of val_dio)
value1
REAL
measured value (definition depends on packet type)
pkt_type->
2,6: Humidity[%]
1: not used
3,5: Y axis acceleration (average value if packet contains multiple samples)[G]
0x101: ADC1[V] ,103: Not used
value2
REAL
measured value (definition depends on packet type)
pkt_type->
2: illuminance[lx], 6: not used
1: not used
3,5: Z axis acceleration (average value if packet contains multiple samples)
[G ]
0x101: ADC2[V], 103: unused
value3
REAL
measurement value (definition depends on packet type)
pkt_type->
2: not used, 6: not used
1: not used
3,5: not used
0x101: ADC3[V], 103: not used
val_vcc_mv
INTEGER
voltage[mV]
val_dio
INTEGER
int32_t
b0..b7: DI1..DI8 values (1 is LO, 0 is HIGH level) b24..b25: magnet value (if b28 is 1), 00->no magnet, 01->N pole, 10->S pole b28: if 1 Magnet data is stored in b24..b25 b31: Regular transmission bit (magnet only)
val_adc1_mv
INTEGER
pkt_type
->1,2,3,0x101: Measured value of ADC1
val_adc2_mv
INTEGER
pkt_type
->0x101: Measured value of ADC4
val_adc2_mv
INTEGER
Other data storage purpose
ev_src
INTEGER
Source of the event
ev_id
INTEGER
Event ID
pal_type
->5: 1.... .6 -> dice 16 -> MOVE ... etc. (see documentation for TWELITE CUE)
ev_param
INTEGER
Event Parameter
Used to store additional information (text) in sensor nodes.
sid
INTEGER
SID above
sid_text
TEXT
SID converted to hexadecimal string (for readability)
desc
TEXT
Auxiliary information corresponding to the SID, to be displayed together in a list, etc.
Used for the purpose of maintaining the last received timestamp.
sid
INTEGER
SID above.
ts
INTEGER
Timestamp of last receipt
lid
Here are some excerpts from the last data received
lqi
pkt_type
value
value1
value2
value3
val_vcc_mw
val_dio
ev_id